FreeBSD检查RAID阵列的状态
时间:2019-11-20 08:53:58 来源:igfitidea点击:
如何在Linux下检查Adaptec RAID阵列的运行状况。
如何查看阵列卡的状态?
在FreeBSD中, aac是Adaptec AdvancedRAID Controller驱动程序。
查看有关RAID设备的信息
执行以下命令:
# dmesg | grep -i RAID
输出示例:
aac0: mem 0xe8000000-0xe81fffff irq 16 at device 0.0 on pci6 aacd0: on aac0
# pciconf -l | grep -i aac
输出:
aac0@pci0:6:0:0: class=0x010400 card=0x02d19005 chip=0x02859005 rev=0x09 hdr=0x00
FreeBSD arcconf
arcconf是Adaptec SCSI RAID系列RAID控制器的命令行界面,用于配置和管理连接的存储设备。
它可用于获取有关RAID配置的详细信息,包括RAID的运行状况。
在FreeBSD中安装arcconf
执行以下命令:
# portsnap fetch update # cd /usr/ports/sysutils/arcconf # make install clean && rehash
如何使用arcconf来查看Adaptec RAID阵列的状态?
获取控制器1的信息:
# /usr/local/sbin/arcconf getconfig 1
输出示例:
Controllers found: 1
----------------------------------------------------------------------
Controller information
----------------------------------------------------------------------
Controller Status : Optimal
Channel description : SAS/SATA
Controller Model : Adaptec 5405
Controller Serial Number : 8C4310BD20D
Physical Slot : 2
Temperature : 58 C/ 136 F (Normal)
Installed memory : 256 MB
Copyback : Disabled
Background consistency check : Disabled
Automatic Failover : Enabled
Global task priority : High
Performance Mode : Default/Dynamic
Stayawake period : Disabled
Spinup limit internal drives : 0
Spinup limit external drives : 0
Defunct disk drive count : 0
Logical devices/Failed/Degraded : 1/0/0
--------------------------------------------------------
Controller Version Information
--------------------------------------------------------
BIOS : 5.2-0 (16501)
Firmware : 5.2-0 (16501)
Driver : 5.2-0 (16501)
Boot Flash : 5.2-0 (16501)
--------------------------------------------------------
Controller Battery Information
--------------------------------------------------------
Status : Optimal
Over temperature : No
Capacity remaining : 99 percent
Time remaining (at current draw) : 3 days, 0 hours, 52 minutes
----------------------------------------------------------------------
Logical device information
----------------------------------------------------------------------
Logical device number 0
Logical device name : RAID1-A
RAID level : 1
Status of logical device : Optimal
Size : 285686 MB
Read-cache mode : Enabled
Write-cache mode : Enabled (write-back)
Write-cache setting : Enabled (write-back) when protected by battery
Partitioned : Yes
Protected by Hot-Spare : No
Bootable : Yes
Failed stripes : No
Power settings : Disabled
--------------------------------------------------------
Logical device segment information
--------------------------------------------------------
Segment 0 : Present (0,0) 3LM44BDA00009839M228
Segment 1 : Present (0,1) 3LM4C6B000009841PEW9
----------------------------------------------------------------------
Physical Device information
----------------------------------------------------------------------
Device #0
Device is a Hard drive
State : Online
Supported : Yes
Transfer Speed : SAS 3.0 Gb/s
Reported Channel,Device(T:L) : 0,0(0:0)
Reported Location : Connector 0, Device 0
Vendor : SEAGATE
Model : ST3300655SS
Firmware : 0004
Serial number : 3LM44BDA00009839M228
World-wide name : 5000C50006EDAD74
Size : 286102 MB
Write Cache : Enabled (write-back)
FRU : None
S.M.A.R.T. : No
Device #1
Device is a Hard drive
State : Online
Supported : Yes
Transfer Speed : SAS 3.0 Gb/s
Reported Channel,Device(T:L) : 0,1(1:0)
Reported Location : Connector 0, Device 1
Vendor : SEAGATE
Model : ST3300655SS
Firmware : 0004
Serial number : 3LM4C6B000009841PEW9
World-wide name : 5000C50006EF88D8
Size : 286102 MB
Write Cache : Enabled (write-back)
FRU : None
S.M.A.R.T. : No
Command completed successfully.

