C# 尝试使用 CoreCon API 连接到设备时获取 DirectoryNotFoundException

声明:本页面是StackOverFlow热门问题的中英对照翻译,遵循CC BY-SA 4.0协议,如果您需要使用它,必须同样遵循CC BY-SA许可,注明原文地址和作者信息,同时你必须将它归于原作者(不是我):StackOverFlow 原文地址: http://stackoverflow.com/questions/6904/
Warning: these are provided under cc-by-sa 4.0 license. You are free to use/share it, But you must attribute it to the original authors (not me): StackOverFlow

提示:将鼠标放在中文语句上可以显示对应的英文。显示中英文
时间:2020-07-31 16:45:08  来源:igfitidea点击:

Getting DirectoryNotFoundException when trying to Connect to Device with CoreCon API

提问by ageektrapped

I'm trying to use the CoreCon API in Visual Studio 2008 to programmatically launch device emulators. When I call device.Connect(), I inexplicably get a DirectoryNotFoundException. I get it if I try it in PowerShell or in C# Console Application. Here's the code I'm using:

我正在尝试使用 Visual Studio 2008 中的 CoreCon API 以编程方式启动设备模拟器。当我打电话时device.Connect(),我莫名其妙地收到 DirectoryNotFoundException。如果我在 PowerShell 或 C# 控制台应用程序中尝试,我会得到它。这是我正在使用的代码:

static void Main(string[] args)
{
     DatastoreManager dm = new DatastoreManager(1033);
     Collection<Platform> platforms = dm.GetPlatforms();

     foreach (var p in platforms)
     {
        Console.WriteLine("{0} {1}", p.Name, p.Id);
     }

     Platform platform = platforms[3];
     Console.WriteLine("Selected {0}", platform.Name);

     Device device = platform.GetDevices()[0];
     device.Connect();
     Console.WriteLine("Device Connected");

     SystemInfo info = device.GetSystemInfo();
     Console.WriteLine("System OS Version:{0}.{1}.{2}",info.OSMajor, info.OSMinor, info.OSBuildNo);

     Console.ReadLine();
}

Does anyone know why I'm getting this error? I'm running this on WinXP 32-bit, plain jane Visual Studio 2008 Pro. I imagine it's some config issue since I can't do it from a Console app or PowerShell.

有谁知道我为什么会收到这个错误?我在 WinXP 32 位普通 jane Visual Studio 2008 Pro 上运行它。我想这是一些配置问题,因为我无法从控制台应用程序或 PowerShell 执行此操作。

Here's the stack trace:

这是堆栈跟踪:

System.IO.DirectoryNotFoundException was unhandled

Message="The system cannot find the path specified.\r\n"

Source="Device Connection Manager"

StackTrace:
       at Microsoft.VisualStudio.DeviceConnectivity.Interop.ConManServerClass.ConnectDevice()
       at Microsoft.SmartDevice.Connectivity.Device.Connect()
       at ConsoleApplication1.Program.Main(String[] args) in C:\Documents and Settings\Thomas\Local Settings\Application Data\Temporary Projects\ConsoleApplication1\Program.cs:line 23
       at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args)
       at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args)
       at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly()
       at System.Threading.ThreadHelper.ThreadStart_Context(Object state)
       at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state)
       at System.Threading.ThreadHelper.ThreadStart()

采纳答案by PrateekSaluja

It can be found at <systemdrive>:\Program files\Common Files\Microsoft Shared\CoreCon\1.0\Bin.

它可以在<systemdrive>:\Program files\Common Files\Microsoft Shared\CoreCon\1.0\Bin

This is the path where you can get this dll, so add this dll to your project.

这是你可以得到这个dll的路径,所以把这个dll添加到你的项目中。

回答by Kev

I tried this and it works ok. Can you paste in the whole exception and stack trace?

我试过这个,它工作正常。你能粘贴整个异常和堆栈跟踪吗?

Updated:Strangely I can't find that interop assy on my machine either other than under the c:\windows\assembly\GAC_MSIL folders.

更新:奇怪的是,除了在 c:\windows\assembly\GAC_MSIL 文件夹下之外,我在我的机器上找不到那个互操作组件。

Why not fire up SysInternals FileMon or Process Monitor, it'd save some guesswork.

为什么不启动 SysInternals FileMon 或 Process Monitor,它会节省一些猜测。

回答by ageektrapped

I suspect there is a problem with my Microsoft.VisualStudio.DeviceConnectivity.Interop assembly. There is no copy of that on disk that I can find. It's in the GAC only. I tried to inspect in Reflector, but it needs that Interop assembly also. Since ConManServerClass is obviously COM, maybe there's a COM library that has to be registered?

我怀疑我的 Microsoft.VisualStudio.DeviceConnectivity.Interop 程序集有问题。我在磁盘上找不到它的副本。它仅在 GAC 中。我尝试在 Reflector 中进行检查,但它也需要该 Interop 程序集。既然ConManServerClass 显然是COM,那么也许有一个必须注册的COM 库?

回答by ageektrapped

Installing VS 2008 SP 1 fixed it for me.

安装 VS 2008 SP 1 为我修复了它。