Dell PowerEdge:PERC 6i控制器拒绝用于重新同步降级阵列的新驱动器
时间:2020-02-23 14:44:06 来源:igfitidea点击:
最近,从带有PERC 6/i RAID控制器的Dell PowerEdge 2950中观察到这种奇怪的行为。
One drive member from a RAID-5 array was failed I pulled out the defective drive and pop in a brand new drive Strangely, it did not started to sync and after a few moment, the drive was identified as bad and I could observe a "Removed"; state from OMSA. I could also notice in the PERC firmware utility that the new drive contain a foreign RAID-0 configuration.
这是我为解决此问题而采取的步骤:
1.不要删除标记为坏/已删除的新驱动器
2.重新启动服务器,然后输入PERC固件实用程序(CTRL + R)
3.卸下标记为已损坏/已卸下的新驱动器(在控制器中)(不要担心,卸下新驱动器后,所有虚拟磁盘信息将在" Controller 0"下消失!)
4.按CTRL + ALT + DEL退出PERC固件
5.引导服务器,使新驱动器脱离托架
6.在阵列降级模式下成功启动服务器后,将新驱动器弹出
您的阵列重建应该很快开始!