JunOS:虚拟机箱在一个单元上关闭vc-port,在另一个单元上打开vc-port
时间:2020-02-23 14:44:18 来源:igfitidea点击:
如果您在EX,QFX或者MX平台上运行Virtual Chassis,并且最终遇到其中一个vc-port出现在一个单元上而另一个出现在另一个单元上的情况,则本讲座适合您!
让我们快速回顾一下该行为:
1.设置为vc-port(SFP +或者QSFP +)接口链接的接口在一个成员上是向上的,在另一成员上是向下的)2. VC-Port(一侧或者两侧)可能显示或者可能不显示CRC错误3. vc-端口状态显示vcp接口已关闭4.日志报告以下错误:
fpc1 PFE: ifl-family(2) platform attach failed for ifd vcp-255/1/2 [Unknown error: -4] fpc1 PFE: ifl-family(2) platform change failed for ifd vcp-255/1/2 [no such file or directory] fpc1 IFRT: ‘IFL family add’ (opcode 35) failed fpc1 ifl 64; pfe family attach error (2) fpc1 [EX-BCM PIC] ex_bcm_linkscan_handler: Link 56 UP
vc-port status的示例:
> show virtual-chassis vc-port fpc0: ------------------------------------------------------------------------- Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC/Port 1/2 Configured -1 Down 40000 1/3 Configured -1 Up 40000 1 vcp-255/1/3 1/1 Configured Absent 1/0 Configured Absent fpc1: ------------------------------------------------------------------------- Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC/Port 1/2 Configured -1 Up 40000 1/3 Configured -1 Up 40000 0 vcp-255/1/3 1/1 Configured Absent 1/0 Configured Absent
另外,发出" show virtual-chassis vc-port"命令会短暂显示" Up"状态,然后显示为" Down"。
以下故障排除尝试未得到任何积极的结果:
- 从vc-port删除接口(将端口转换回标准以太网/上行链路接口)
- 将删除的接口重新添加为vc-port(将以太网/上行链路转换为vc-port)
- 卸下SFP +/QSFP +光纤并重新插入
- 重新启动VC的两个参与成员
上面的步骤是在实验室中为测试目的而尝试的,由于我从一开始就怀疑光学器件,因此不可能给出积极的结果。
由于链路状态行为,很可能是故障SFP +/QSFP +模块。
尝试首先更换链接显示为向下的一侧。
但是,这并不意味着它所显示的那边是错误的,而可能恰恰相反! (在我的情况下,状态为链接状态的那一个是错误的)。
更换光纤后,应再次备份该vc-port链接。
注意:如果这是在不久前部署的活动机箱上发生的,则以前可能已经观察到故障的早期迹象,这是由于端口抖动和系统负载增加。